Input Measured variable Displacement Measuring range 50-3000mm Output Start-Stop pulse RS 422 differential signal Accuracy -Resolution 0.1mm/0.01mm/0.005mm -Linearity <0.002%F.S -Repeatability <0.001%F.S -Update frequence Controller dependent Operating conditions Magnet speed Any Operating pressure 350bar Operating temperature -40℃…100℃ Dew point,humidity 90% rel. humidity,no condensation Sealing IP67 if mating connector is correctly fitted Shock test 100g single hit,IEC-Standard 68-2-27 Vibration test 10g/10-2000Hz,IEC-Standard 68-2-2 Norms,EMC test Electromagnetic emission EN 50081-1 Electromagnetic im munity EN 50082-2 EN 61000,Criteria A,CE-qualified Form factor,material Sensor head Aluminum Rod with flange Stainless steel 1.4301/SS X5CrNi1810 Position transimitter Ring-or U-Magnet Installation Mounting position Any Rod Threaded flange M18*1.5 or 3/4”-16 UNF-3A,hex net M18 Magnet Mounting plate and screws:amagnetic Electrical connection Connection type 6 pin connector M16 or 2 m cable outlet Input voltage 24VDC Current consumption 100mA typical Ripple <1% peak-peak Electric strength 500V(DC ground to machine ground)
|