Input Measuring variable position Stroke length 50…2500 mm Output Current 4…20 mA or 20…4 mA (min/max. load: 0/500 Ohms) Accuracy Resolution infinite Linearity 1 < ± 0.02 % F.S. (minimum ± 60 μm) Repeatability < ± 0.002 % F.S. (minimum ± 20 μm) Update frequency, stroke dependent < 3 kHz Ripple < 0.01 % F.S. Operating conditions Mounting position any Magnet speed any Operating temperature -40 °C…+85 °C Dew point, humidity 90 % rel. humidity, no condensation Ingress protection IP67 (with professional mounted housing and connectors), sensor with flat connector Shock test 100 g (single shock) IEC-Standard 60068-2-27 Vibration test 15 g / 10…2000 Hz IEC-Standard 60068-2-6 (resonance frequencies excluded) EMC test Electromagnetic emission EN 55011, cl. B:2009 + A1:2010 Electromagnetic immunity EN 61326-1:2006 Design / Material Sensor housing stainless steel 1.4301 / AISI 304 Rod stainless steel 1.4301 / AISI 304 10 mm rod: 350 bar, 530 bar peak Position magnet ring magnet, PA-Ferrite Installation Mounting type embedded Mounting position any Electrical connection Connection type 6 pin molex Supply voltage 24 VDC (+20 % / -15 %) Current consumption 50…140 mA Ripple < 0.28 Vpp Electric strength 500 VDC (0 V ground to machine ground) Polarity protection up to -30 VDC
|