Input Measured variable position Stroke length 50…1500 mm Output 1. Voltage 0…10 VDC or 10…0 VDC, 0…10 VDC and 10…0 VDC (min. load controller > 5 kOhms) 2. Current 4…20 mA or 20…4 mA (min./max. load: 0/500 Ohms) 3. Start/Stop RS-422 differential signal for position additional available: serial parameter upload of stroke length, offset,gradient, status and manufacturer number Accuracy Resolution analog: infinite start/stop: 0.1 / 0.01 / 0.005 mm Linearity < ± 0.02 % F.S. (minimum ± 60 μm) Repeatability < ± 0.005 % F.S. (minimum ± 20 μm) Update frequency, stroke dependent analog: < 3 kHz / start/stop: controller dependent Ripple analog: < 0.01 % F.S. / start/stop: controller dependent Mounting position any Magnet speed any Operating temperature -40 °C…+75 °C Dew point, humidity 90 % rel. humidity, no condensation Electronic ingress protection 1 IP67 if mating cable connector is correctly fitted Shock test 100 g (single shock) IEC-Standard 60068-2-27 Vibration test 10 g / 10…2000 Hz IEC-Standard 60068-2-6 (resonance frequencies excluded) EMC test Electromagnetic emission EN 61000-6-4 (for use in industrial environment) Electromagnetic susceptibility EN 61000-6-2 The sensor meets the requirements of the EC directives and is marked with CE Desigh/Material Sensor housing aluminum Piston aluminum Installation Mounting type adjustable mounting feet or adjustable rod ends M6 Mounting position any Eletrical connection Connection type 5 pin connector M12 (analog); 8 pin connector M12 (start/stop) Supply voltage 24 VDC (+20 % / -15 %) Current consumption 50…140 mA (start/stop 50…100 mA) Ripple < 0.28 Vpp Electric strength 500 VDC (DC ground to machine ground) Polarity protection up to -30 VDC Overvoltage protection up to 36 VDC
|