Input Measured value position Stroke length 25…3250 mm Output Voltage 0…10 VDC and 10…0 VDC (min. load controller: > 5 kOhms) Current 4(0)…20 mA or 20…4(0) mA (min./max. load: 0/500 Ohms) Programming programming of set points using optional accessories 2 Accuracy Resolution 16 bit (minimum 1 μm) Linearity < ±0.02 % F.S. (minimum ±60 μm) Repeatability ≤ ±0.005 % F.S. (minimum ±20 μm) Sample rate up to 1200 mm: 0.5 ms up to 2400 mm: 1 ms > 2400 mm: 2 ms Operating conditions Magnet movement velocity any Operating temperature –40…+90 °C, Option –40…+100 °C Operating pressure 350 bar, 700 bar peak (at 10×1 min) Ingress protection IP67 with proper mating connector IP68 for cable outlet Shock test 100 g (single shock) / IEC-Standard 60068-2-27 Vibration test 15 g / 10…2000 Hz, IEC-Standard 60068-2-6 (resonance frequencies excluded) EMC test electromagnetic emission according to EN 61000-6-4 electromagnetic immunity according to EN 61000-6-2 The sensor meets the requirements of the EC directives and is marked with CE Design/Material Sensor electronics housing stainless steel 1.4305 / AISI 303 3 Sensor rod with flange stainless steel 1.4306; 1.4307 / AISI 304 L Position magnet ring magnet, PA ferrite Installation Mounting position any Mounting fitting flange Ø 18 f7, 6 bores for machine screws (ISO 4762) Electrical connection Connection type cable gland M12 a-code (5 pin) M16 (6 pin) Operating voltage +24 VDC (+20 % / −15 %) Current consumption 100 mA typically dependent on stroke length Ripple ≤ 0.28 Vpp Dielectric strength 500 VDC (DC ground to machine ground)
|