OUTPUT Measured output Position variables: Resolution: Analog: Infinite (restricted by output ripple) Update times: < 1 ms (typical) Linearity deviation: < ± 0.02% full stroke (minimum ± 50 μm) Repeatability: < ± 0.001% of full stroke (minimum ± 2.5 μm) Hysteresis: < 4 μm Analog Outputs: 2 output channels Voltages (Fully adjustable): 0 to 10, 10 to 0, -10 to +10, +10 to -10 Vdc (minimum controller load > 5k ohms) Current (Fully adjustable): 4 (0) to 20 mA, 20 to 4 (0) mA (min./max. load 0/500 ohms) Stroke Length: 50 mm (2 in.) to 2540 mm (100 in.) ELECTRONICS Operating voltage: +24 Vdc nominal Current drain:100 mA typical per channel Dielectric withstand voltage: 500 Vdc (DC ground to machine ground) Setpoints: Setpoint adjustment (Null/Span): 100% of electrical stroke length, 50 mm (2 in.) minimum distance between setpoints. ENVIRONMENTAL Operating conditions: Operating temperature: -20 °C (-4 °F) to +75 °C (167 °F) for power EMC test: Immunity: EN61326-1 Shock rating: 100 g (single hit) / IEC 60068-2-27 (survivability) Vibration rating: 10 g / 10 to 2000 Hz, IEC 60068-2-6 (operational) Connection type: Integral cable ROD STYLE SENSOR (MODEL GTE) Electronic head: 303 stainless steel Sealing: IP54 Sensor rod: 304L stainless steel Operating pressure: 350 bar static, 690 bar peak
|