Input Measured value position, the position is measured separately on two or three position measuring systems. Stroke length 50…2900 mm Output Voltage 0…10 / 10…0 / -10…+10 / +10…-10 VDC (min. load controller: > 5 kOhms) Current 4(0)…20 mA / 20…4(0) mA (min/max. load: 0 / 500 Ohms) Null position/end position adjustment 100 % of electrical stroke (minimal range 50 mm) Accuracy Position measurement: – Resolution analog – Linearity 1 < ± 0.02 % F.S. (minimum ± 50 μm) – Repeatability < ± 0.001 % F.S. (minimum ± 2.5 μm) – Hysteresis < 4 μm – Sample rate < 2.5 ms – Ripple < 0.01 % F.S. Operating conditions Magnet movement velocity any Operating temperature electronic housing -40…+75 °C Dew point, humidity 90% rel. humidity, no condensation Ingress protection IP67, IP68 for cable outlet (with proper mating connector) Shock test 100 g (single shock) IEC standard 60068-2-27 Vibration test 5 g / 10…2000 Hz IEC standard 60068-2-6 (resonance frequencies excluded) EMC test electromagnetic emission EN 61000-6-4 (for use in industrial environment) electromagnetic immunity EN 61000-6-2 The sensor meets the requirements of the EC directives and is marked with CE. Design / Material Sensor electronics housing aluminum Sensor rod with flange stainless steel 1.4301 / AISI 304 Operating pressure 350 bar, 690 bar peak Position magnet Ring magnets, U-magnets Installation Mounting position any orientation Sensor rod threaded flange M18 × 1.5 Position magnet mounting plate and screws from antimagnetical material Electrical connection Connection type 6 pin connector M16 or integral PUR-cable Operating voltage 24 VDC (-15 / +20 %) Current consumption 100 mA typical (each channel) Ripple ≤ 0.28 Vpp Dielectric strength 500 VDC (DC ground to machine ground) Polarity protection up to -30 VDC Overvoltage protection up to 36 VDC
|