Input Measured variables – Position – Velocity – Multi-position measurement max. 20 positions (CANbus, Profibus, EtherCAT) Stroke length 25…5000 mm Output Interfaces Analog, SSI, CANbus, Profibus-DP, EtherCAT Accuracy Resolution Output dependent Linearity < ± 0.02 % F.S. (Minimum ± 50 μm)1 Repeatability < ± 0.001 % F.S. (Minimum ± 2.5 μm) Hysteresis < 4 μm Ripple/Jitter Analog: 0.01 % F.S. / Digital: < ± 10 μm Operating conditions Magnet speed Any Operating temperature -40 °C…+75 °C Dew point, humidity 90% rel. humidity, no condensation Ingress protection Sensor electronics IP67 (with professional mounted housing and connectors) Measuring rod with connecting cable for side cable entry IP65 Measuring rod with single wires and flat connector with bottom cable entry IP30 Shock test 100 g (single shock IEC-Standard 60068-2-27) Vibration test 10 g / 10 – 2000 Hz IEC-Standard 60068-2-6 Standards, EMC test2 Electromagnetic emission EN 61000-6-4 Electromagnetic immunity EN 61000-6-2 EN 61000-4-2/3/4/6, Level 3/4, criterium A Design, material Diagnostic display LED beside connector Sensor electronics Aluminum Measuring rod with flange Stainless steel 1.4301 / AISI 304 Operating pressure 350 bar, (700 bar peak) for hydraulic rod Position magnet Ring magnets Electrical connection Connection type Connector or cable outlet (output dependent) Supply voltage 24 VDC (-15 / +20 %) – Polarity protection up to -30 VDC – Overvoltage protection up to 36 VDC Current drain 100 mA typical Ripple ≤ 0.28 Vpp Electric strength 500 VDC (DC ground to machine ground)
|