Input Measured variables – Position – Velocity – Multi-position measurement max. 20 positions (CANbus, Profibus, EtherCAT) Stroke length 100…20,000 mm Output Interfaces Analog, SSI, CANbus, Profibus-DP, EtherCAT Accuracy Resolution output dependent Linearity < ± 0.02 % F.S. (Minimum ± 100 μm) Repeatability < ± 0.001 % F.S. (Minimum ± 2.5 μm) Hysteresis < 4 μm Operating conditions Magnet speed any Operating temperature -40 °C…+75 °C Dew point, humidity 90% rel. humidity, no condensation Ingress protection1 IP30 (IP65 rating only for professional mounted guide pipe IP65 and if mating connectors are correctly fitted) Shock test 100 g (single shock IEC-Standard 60068-2-27) Vibration test 5 g / 10 – 150 Hz IEC-Standard 60068-2-6 Standards, EMC test Electromagnetic emission EN 61000-6-4 Electromagnetic immunity EN 61000-6-2 EN 61000-4-2/3/4/6, Level 3/4, Criterium A Design, Material Diagnostic display LEDs beside connector Sensor head Aluminum-diecasting housing Sensor stroke Flexible plastic pipe, min. bend radius 250 mm, radius for shipping 400 mm Position magnet Permanent magnet Electrical connection Connection type Connector or cable outlet (output dependent) Supply voltage 24 VDC (-15 / +20 %) – Polarity protection up to -30 VDC – Overvoltage protection up to 36 VDC Current drain 100 mA typical Ripple ≤ 0.28 Vpp Electric strength 500 VDC (DC ground to machine ground)
|