Power supply / I/O Specifications | Power supply | 100 V to 120 V AC / 200 V to 240 V AC/100 V to 240 V AC, 24 V DC (varies with different models) |
---|
Input | 12 V to 24 V DC, 24 V DC ±common |
---|
Output | Relay 2 A to 5 A / Transistor 0.1 A to 0.5 A (varies with different models) |
---|
Performance Specifications | Number of I/O points | Up to 768 points |
---|
Expansion | Up to 1 backplane Max. number of I/O points: 1,600 Remote I/O: 8192 points |
---|
Operation speed | 0.03µs/step (Basic instuction) |
---|
Built-in memory | RAM (ROM/Small PC card is optional) |
---|
Memory capacity | Approx. 32k steps/Approx. 60k steps/Approx. 120k steps (varies with defferent models) |
---|
Operation memory | Internal relay | 14192 points |
---|
Timer/Counter(T/C) | 3072 points in total |
---|
Data register | 10240 words |
---|
File register | 32765 words × 3 banks |
---|
Special Functions | Analog I/O | Available by adding analog input and analog output units. |
---|
High speed counter | Available by adding high-speed counter unit. (Max. 200 kHz) |
---|
Pulse output | Positioning unit 2-axis Positioning unit 4-axis |
---|
Interrupt input | Available by adding high-speed counter unit or pulse I/O unit. |
---|
Special Network Functions | Serial communication | RS232C, RS485, RS422, Modem |
---|
Remote I/O | S-LINK, S-LINK V or MEWNET-F |
---|
PLC link | MEWNET-W2(Wire), MEWNET-W0, MEWNET-VE or FL-NET |
---|
Other Built-in Functions | Program block-edit during RUN | Available |
---|
Constant scan | Available |
---|
Clock/Calendar function | Built-in type |
---|