Programming method / Control method | Relay symbol / Cyclic operation |
---|
Number of I/O points | No expansion (Control unit only) | 10 points [Input: 6, Relay output: 4] | 14 points [Input: 8, Relay output: 6] | 16 points [Input: 8, Transistor output: 8] |
---|
With expansion 1 * Same type of control and expansion units | Max. 58 points | Max. 62 points | Max. 112 points |
---|
With expansion 2 * Mix type of relay and transistor units | Max. 106 points | Max. 110 points | Max. 112 points |
---|
Program memory | EEPROM (no backup battery required) |
---|
Program capacity | 16 k steps |
---|
Number of instructions | Basic | 110 approx. |
---|
High-level | 210 approx. |
---|
Operation speed | Up to 3,000 steps | Basic instructions: 0.08 μs Min. Timer instructions: 2.2 μs Min. High-level instructions: 0.32 μs (MV instruction) Min. |
---|
3,001st and later steps | Basic instructions: 0.58 μs Min. Timer instructions: 3.66 μs Min. High-level instructions: 1.62 μs (MV instruction) Min. |
---|
Operation memory | Relay | Internal relay (R) | 4,096 points |
---|
Timer / Counter (T / C) | 1,024 points |
---|
Memory area | Data register (DT) | 12,315 words |
---|
Index register (IX, IY) | 14 words (IO to ID) |
---|
Master control relay points (MCR) | 256 words |
---|
Number of labels (JMP and LOOP) | 256 labels |
---|
Differential points | Equivalent to the program capacity |
---|
Number of step ladder | 1,000 stages |
---|
Number of subroutines | 500 subroutines |
---|
Special functions | High speed counter | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each)* |
---|
Pulse output | Not available | 4 points (50 kHz max. each) Two channels can be controlled individually.* |
---|
PWM output | Not available | 4 points (6 Hz to 4.8 kHz) |
---|
Pulse catch input / interrupt input | Total 8 points (with high speed counter) |
---|
Interrupt program | Input: 8 programs (6 programs for C10 only) / Periodic: 1 program / Pulse match: 4 programs/td> |
---|
Periodical interrupt | In units of 0.5 ms: 0.5 ms to 1.5 sec. / In units of 10 ms: 10 ms to 30 sec. |
---|
Constant scan | In units of 0.5 ms: 0.5 ms to 600 ms |
---|
RS232C port | One RS232C port is mounted on each of C10CRS, C10CRM, C14CRS, C14CRM, C16CT, C16CP, C32CT, C32CP, T32CT, T32CP, F32CT and F32CP type (3P terminal block) Transmission speed (Baud rate): 2,400 to 115,200 bits/s, Transmission distance: 15 m 9.8 ft. Communication method: half duplex |
---|
RS485 port | One RS485 port is mounted on each of C10MRS, C14MRS, C16MT, C16MP, C32MT, C32MP, T32MT, T32MP, F32MT and F32MP type(3P terminal block) Transmission speed (Baud rate): 115.2 kbps (It is possible to change to 19.2 kbps by the setting.), Transmission distance: 1,200 m 3,937 ft, Communication method: half duplex |
---|
Maintenance | Memory backup | Program and system register | Stored program and system register in EEPROM |
---|
Operation memory | Stored fixed area in EEPROM Counter: 16 points Internal relay: 128 points Data register: 315 words |
---|
Self-diagnostic function | Watchdog timer (690 ms approx.), Program syntax check |
---|
Real-time clock function | Not available |
---|
Other functions | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection |
---|